Share Email Print
cover

Proceedings Paper • new

integrated intra-cardiac catheter for polarization sensitive optical coherence tomography-guided radiofrequency ablation (Conference Presentation)
Author(s): Xiaowei Zhao; Colin Blumenthal; Kilinc U. Orhan; Deniz Dosluoglu; Michael W. Jenkins; Christopher Snyder; Mauricio Arruda; Andrew M. Rollins
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Cardiac arrhythmias are a major source of mortality in the United States. Ablation is the only curative therapy for cardiac arrhythmias, and catheter-based radiofrequency ablation (RFA) through percutaneous access has emerged as the standard care for many arrhythmias. However, current procedures only monitor temperature, impedance and pressure measurements during ablation, which results in incomplete lesion formation (e.g., high recurrence rate for atrial fibrillation patients) and complications. In our previous work, we have shown integration of a commercially available RFA catheter with polarization sensitive optical coherence tomography (PSOCT). This was accomplished by housing the PSOCT probe inside of the RFA catheter with a window at the catheter tip that allows for forward viewing PSOCT imaging. Data from ex vivo experiments have shown that the integrated RFA catheter can be used to confirm catheter tissue apposition and monitor tissue change during ablation by measuring retardance. It was also demonstrated that the PSOCT window does not interfere with normal lesion formation. However, only the catheter tip was integrated, enabling only in vitro experiments. Therefore, we have developed a fully integrated PSOCT RFA catheter based on a commercially available catheter to enable experiments in living swine via percutaneous access. By properly choosing a middle layer sheath to house the PSOCT probe, we reduced the non-uniform rotation distortion (NURD), reduced PSOCT probe tip longitudinal movement due to winding back, improved image quality and stability. Further validation of functionality by simulating RFA procedures in living swine through percutaneous access is ongoing.

Paper Details

Date Published: 14 March 2018
PDF
Proc. SPIE 10471, Diagnostic and Therapeutic Applications of Light in Cardiology 2018, 104710P (14 March 2018); doi: 10.1117/12.2290560
Show Author Affiliations
Xiaowei Zhao, Case Western Reserve Univ. (United States)
Colin Blumenthal, Case Western Reserve Univ. (United States)
Kilinc U. Orhan, Case Western Reserve Univ. (United States)
Deniz Dosluoglu, Case Western Reserve Univ. (United States)
Michael W. Jenkins, Case Western Reserve Univ. (United States)
Christopher Snyder, Case Western Reserve Univ. (United States)
Mauricio Arruda, Case Western Reserve Univ. (United States)
Andrew M. Rollins, Case Western Reserve Univ. (United States)


Published in SPIE Proceedings Vol. 10471:
Diagnostic and Therapeutic Applications of Light in Cardiology 2018
Guillermo J. Tearney; Kenton W. Gregory; Laura Marcu, Editor(s)

© SPIE. Terms of Use
Back to Top