Share Email Print
cover

Proceedings Paper

Spatio-temporal analysis of blood perfusion by imaging photoplethysmography
Author(s): Sebastian Zaunseder; Alexander Trumpp; Hannes Ernst; Michael Förster; Hagen Malberg
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Imaging photoplethysmography (iPPG) has attracted much attention over the last years. The vast majority of works focuses on methods to reliably extract the heart rate from videos. Only a few works addressed iPPGs ability to exploit spatio-temporal perfusion pattern to derive further diagnostic statements.

This work directs at the spatio-temporal analysis of blood perfusion from videos. We present a novel algorithm that bases on the two-dimensional representation of the blood pulsation (perfusion map). The basic idea behind the proposed algorithm consists of a pairwise estimation of time delays between photoplethysmographic signals of spatially separated regions. The probabilistic approach yields a parameter denoted as perfusion speed. We compare the perfusion speed versus two parameters, which assess the strength of blood pulsation (perfusion strength and signal to noise ratio).

Preliminary results using video data with different physiological stimuli (cold pressure test, cold face test) show that all measures are influenced by those stimuli (some of them with statistical certainty). The perfusion speed turned out to be more sensitive than the other measures in some cases. However, our results also show that the intraindividual stability and interindividual comparability of all used measures remain critical points.

This work proves the general feasibility of employing the perfusion speed as novel iPPG quantity. Future studies will address open points like the handling of ballistocardiographic effects and will try to deepen the understanding of the predominant physiological mechanisms and their relation to the algorithmic performance.

Paper Details

Date Published: 20 February 2018
PDF: 14 pages
Proc. SPIE 10501, Optical Diagnostics and Sensing XVIII: Toward Point-of-Care Diagnostics, 105010X (20 February 2018); doi: 10.1117/12.2289896
Show Author Affiliations
Sebastian Zaunseder, TU Dresden (Germany)
Alexander Trumpp, TU Dresden (Germany)
Hannes Ernst, TU Dresden (Germany)
Michael Förster, TU Dresden (Germany)
Hagen Malberg, TU Dresden (Germany)


Published in SPIE Proceedings Vol. 10501:
Optical Diagnostics and Sensing XVIII: Toward Point-of-Care Diagnostics
Gerard L. Coté, Editor(s)

© SPIE. Terms of Use
Back to Top