Share Email Print
cover

Proceedings Paper

Bus current analysis of high power cryocooler's controller
Author(s): Zhanlei Jin; Qiyang Sun; Liqun Dai; Jie Dong
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Current analysis was an important research content for reducing power of cryocooler’s controller. Simulation was done among load current, H bridge current and power current refer to 42V bus power voltage. Then relationship among IL1, IC1, ρ and IM1 was established. Simulation results indicate that IL1-max, IL1-ave, IL1-rms, IC1-min and IC1-ave were linearly increasing to ρ and IM1, especially IL1-rms ≈ 0.612ρ IM1-max . IC1-rms increase firstly then decrease with the increasing of ρ. IC1-rms reaches maximum when ρ=0.8, then ICL-rms =(12.32/RM1 + 0.98) exp -((ρ-0.78)/0.57)2. The results were useful for miniaturizing cryocooler’s controller.

Paper Details

Date Published: 8 March 2017
PDF: 9 pages
Proc. SPIE 10255, Selected Papers of the Chinese Society for Optical Engineering Conferences held October and November 2016, 102552G (8 March 2017); doi: 10.1117/12.2269254
Show Author Affiliations
Zhanlei Jin, Beijing Institute of Space Mechanics and Electricity (China)
Qiyang Sun, Beijing Institute of Space Mechanics and Electricity (China)
Liqun Dai, Beijing Institute of Space Mechanics and Electricity (China)
Jie Dong, Beijing Institute of Space Mechanics and Electricity (China)


Published in SPIE Proceedings Vol. 10255:
Selected Papers of the Chinese Society for Optical Engineering Conferences held October and November 2016
Yueguang Lv; Jialing Le; Hesheng Chen; Jianyu Wang; Jianda Shao, Editor(s)

© SPIE. Terms of Use