Share Email Print
cover

Proceedings Paper

Performance evaluation of algebraic reconstruction technique (ART) for prototype chest digital tomosynthesis (CDT) system
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Chest digital tomosynthesis (CDT) is a new 3D imaging technique that can be expected to improve the detection of subtle lung disease over conventional chest radiography. Algorithm development for CDT system is challenging in that a limited number of low-dose projections are acquired over a limited angular range. To confirm the feasibility of algebraic reconstruction technique (ART) method under variations in key imaging parameters, quality metrics were conducted using LUNGMAN phantom included grand-glass opacity (GGO) tumor. Reconstructed images were acquired from the total 41 projection images over a total angular range of ±20°. We evaluated contrast-to-noise ratio (CNR) and artifacts spread function (ASF) to investigate the effect of reconstruction parameters such as number of iterations, relaxation parameter and initial guess on image quality. We found that proper value of ART relaxation parameter could improve image quality from the same projection. In this study, proper value of relaxation parameters for zero-image (ZI) and back-projection (BP) initial guesses were 0.4 and 0.6, respectively. Also, the maximum CNR values and the minimum full width at half maximum (FWHM) of ASF were acquired in the reconstructed images after 20 iterations and 3 iterations, respectively. According to the results, BP initial guess for ART method could provide better image quality than ZI initial guess. In conclusion, ART method with proper reconstruction parameters could improve image quality due to the limited angular range in CDT system.

Paper Details

Date Published: 9 March 2017
PDF: 6 pages
Proc. SPIE 10132, Medical Imaging 2017: Physics of Medical Imaging, 101325V (9 March 2017); doi: 10.1117/12.2255647
Show Author Affiliations
Haenghwa Lee, Yonsei Univ. (Korea, Republic of)
Sunghoon Choi, Yonsei Univ. (Korea, Republic of)
Byungdu Jo, Yonsei Univ. (Korea, Republic of)
Hyemi Kim, Yonsei Univ. (Korea, Republic of)
Donghoon Lee, Yonsei Univ. (Korea, Republic of)
Dohyeon Kim, Yonsei Univ. (Korea, Republic of)
Seungyeon Choi, Yonsei Univ. (Korea, Republic of)
Youngjin Lee, Eulji Univ. (Korea, Republic of)
Hee-Joung Kim, Yonsei Univ. (Korea, Republic of)


Published in SPIE Proceedings Vol. 10132:
Medical Imaging 2017: Physics of Medical Imaging
Thomas G. Flohr; Joseph Y. Lo; Taly Gilat Schmidt, Editor(s)

© SPIE. Terms of Use
Back to Top