First experience with x-ray dark-field radiography for human chest imaging (Conference Presentation)
Author(s): Peter B. Noel; Konstantin Willer; Alexander A. Fingerle; Lukas B. Gromann; Fabio De Marco; Kai H. Scherer; Julia Herzen; Klaus Achterhold; Bernhard Gleich; Daniela Münzel; Martin Renz; Bernhard C. Renger; Florian Fischer; Christian Braun; Sigrid Auweter; Katharina Hellbach; Maximilian F. Reiser; Tobias Schröter; Jürgen Mohr; Andre Yaroshenko; Hanns-Ingo Maack; Thomas Pralow; Hendrik van der Heijden; Roland Proksa; Thomas Köhler; Nataly Wieberneit; Karsten Rindt; Ernst J. Rummeny; Franz Pfeiffer
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Purpose: To evaluate the performance of an experimental X-ray dark-field radiography system for chest imaging in humans and to compare with conventional diagnostic imaging. Materials and Methods: The study was institutional review board (IRB) approved. A single human cadaver (52 years, female, height: 173 cm, weight: 84 kg, chest circumference: 97 cm) was imaged within 24 hours post mortem on the experimental x-ray dark-field system. In addition, the cadaver was imaged on a clinical CT system to obtain a reference scan. The grating-based dark-field radiography setup was equipped with a set of three gratings to enable grating-based dark-field contrast x-ray imaging. The prototype operates at an acceleration voltage of up to 70 kVp and with a field-of-view large enough for clinical chest x-ray (>35 x 35 cm2). Results: It was feasible to extract x-ray dark-field signal of the whole human thorax, clearly demonstrating that human x-ray dark-field chest radiography is feasible. Lung tissue produced strong scattering, reflected in a pronounced x-ray dark-field signal. The ribcage and the backbone are less prominent than the lung but are also distinguishable. Finally, the soft tissue is not present in the dark-field radiography. The regions of the lungs affected by edema, as verified by CT, showed less dark-field signal compared to healthy lung tissue. Conclusion: Our results reveal the current status of translating dark-field imaging from a micro (small animal) scale to a macro (patient) scale. The performance of the experimental x-ray dark-field radiography setup offers, for the first time, obtaining multi-contrast chest x-ray images (attenuation and dark-field signal) from a human cadaver.

Paper Details

Date Published: 2 May 2017
PDF: 1 pages
Proc. SPIE 10132, Medical Imaging 2017: Physics of Medical Imaging, 1013215 (2 May 2017); doi: 10.1117/12.2255596
Show Author Affiliations
Peter B. Noel, Klinikum rechts der Isar der Technischen Univ. München (Germany)
Konstantin Willer, Technische Univ. München (Germany)
Alexander A. Fingerle, Klinikum rechts der Isar der Technischen Univ. München (Germany)
Lukas B. Gromann, Technische Univ. München (Germany)
Fabio De Marco, Technische Univ. München (Germany)
Kai H. Scherer, Technische Univ. München (Germany)
Julia Herzen, Technische Univ. München (Germany)
Klaus Achterhold, Technische Univ. München (Germany)
Bernhard Gleich, Technische Univ. München (Germany)
Daniela Münzel, Klinikum rechts der Isar der Technischen Univ. München (Germany)
Martin Renz, Klinikum rechts der Isar der Technischen Univ. München (Germany)
Bernhard C. Renger, Klinikum rechts der Isar der Technischen Univ. München (Germany)
Florian Fischer, Ludwig-Maximilians-Univ. München (Germany)
Christian Braun, Ludwig-Maximilians-Univ. München (Germany)
Sigrid Auweter, Ludwig-Maximilians-Univ. München (Germany)
Katharina Hellbach, Ludwig-Maximilians-Univ. München (Germany)
Maximilian F. Reiser, Ludwig-Maximilians-Univ. München (Germany)
Tobias Schröter, Karlsruher Institut für Technologie (Germany)
Jürgen Mohr, Karlsruher Institut für Technologie (Germany)
Andre Yaroshenko, Philips Healthcare (Germany)
Hanns-Ingo Maack, Philips Healthcare (Germany)
Thomas Pralow, Philips Healthcare (Germany)
Hendrik van der Heijden, Philips Healthcare (Germany)
Roland Proksa, Philips Healthcare (Germany)
Thomas Köhler, Philips Healthcare (Germany)
Nataly Wieberneit, Philips Healthcare (Germany)
Karsten Rindt, Philips Healthcare (Germany)
Ernst J. Rummeny, Klinikum rechts der Isar der Technischen Univ. München (Germany)
Franz Pfeiffer, Technische Univ. München (Germany)


Published in SPIE Proceedings Vol. 10132:
Medical Imaging 2017: Physics of Medical Imaging
Thomas G. Flohr; Joseph Y. Lo; Taly Gilat Schmidt, Editor(s)

© SPIE. Terms of Use
Back to Top