Automatically detecting anatomy orientation is an important task in medical image analysis. Specifically, the ability to automatically detect coarse orientation of structures is useful to minimize the effort of fine/accurate orientation detection algorithms, to initialize non-rigid deformable registration algorithms or to align models to target structures in model-based segmentation algorithms. In this work, we present a deep convolution neural network (DCNN)-based method for fast and robust detection of the coarse structure orientation, i.e., the hemi-sphere where the principal axis of a structure lies. That is, our algorithm predicts whether the principal orientation of a structure is in the northern hemisphere or southern hemisphere, which we will refer to as UP and DOWN, respectively, in the remainder of this manuscript. The only assumption of our method is that the entire structure is located within the scan’s field-of-view (FOV). To efficiently solve the problem in 3D space, we formulated it as a multi-planar 2D deep learning problem. In the training stage, a large number coronal-sagittal slice pairs are constructed as 2-channel images to train a DCNN to classify whether a scan is UP or DOWN. During testing, we randomly sample a small number of coronal-sagittal 2-channel images and pass them through our trained network. Finally, coarse structure orientation is determined using majority voting. We tested our method on 114 Elbow MR Scans. Experimental results suggest that only five 2-channel images are sufficient to achieve a high success rate of 97.39%. Our method is also extremely fast and takes approximately 50 milliseconds per 3D MR scan. Our method is insensitive to the location of the structure in the FOV.

Paper Details

Date Published: 24 February 2017
PDF: 6 pages
Proc. SPIE 10133, Medical Imaging 2017: Image Processing, 1013303 (24 February 2017); doi: 10.1117/12.2254647
Show Author Affiliations
Parmeet S. Bhatia, Siemens Healthineers (United States)
Fitsum Reda, Nvidia (United States)
Martin Harder, Siemens Healthineers (Germany)
Yiqiang Zhan, Siemens Healthineers (United States)
Xiang Sean Zhou, Siemens Healthineers (United States)


Published in SPIE Proceedings Vol. 10133:
Medical Imaging 2017: Image Processing
Martin A. Styner; Elsa D. Angelini, Editor(s)

© SPIE. Terms of Use
Back to Top