Share Email Print
cover

Proceedings Paper

Automated framework for estimation of lung tumor locations in kV-CBCT images for tumor-based patient positioning in stereotactic lung body radiotherapy
Author(s): Satoshi Yoshidome; Hidetaka Arimura; Koutarou Terashima; Masakazu Hirakawa; Taka-aki Hirose; Junichi Fukunaga; Yasuhiko Nakamura
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Recently, image-guided radiotherapy (IGRT) systems using kilovolt cone-beam computed tomography (kV-CBCT) images have become more common for highly accurate patient positioning in stereotactic lung body radiotherapy (SLBRT). However, current IGRT procedures are based on bone structures and subjective correction. Therefore, the aim of this study was to evaluate the proposed framework for automated estimation of lung tumor locations in kV-CBCT images for tumor-based patient positioning in SLBRT. Twenty clinical cases are considered, involving solid, pure ground-glass opacity (GGO), mixed GGO, solitary, and non-solitary tumor types. The proposed framework consists of four steps: (1) determination of a search region for tumor location detection in a kV-CBCT image; (2) extraction of a tumor template from a planning CT image; (3) preprocessing for tumor region enhancement (edge and tumor enhancement using a Sobel filter and a blob structure enhancement (BSE) filter, respectively); and (4) tumor location estimation based on a template-matching technique. The location errors in the original, edge-, and tumor-enhanced images were found to be 1.2 ± 0.7 mm, 4.2 ± 8.0 mm, and 2.7 ± 4.6 mm, respectively. The location errors in the original images of solid, pure GGO, mixed GGO, solitary, and non-solitary types of tumors were 1.2 ± 0.7 mm, 1.3 ± 0.9 mm, 0.4 ± 0.6 mm, 1.1 ± 0.8 mm and 1.0 ± 0.7 mm, respectively. These results suggest that the proposed framework is robust as regards automatic estimation of several types of tumor locations in kV-CBCT images for tumor-based patient positioning in SLBRT.

Paper Details

Date Published: 9 March 2017
PDF: 6 pages
Proc. SPIE 10132, Medical Imaging 2017: Physics of Medical Imaging, 101322F (9 March 2017); doi: 10.1117/12.2253857
Show Author Affiliations
Satoshi Yoshidome, Kyushu Univ. Beppu Hospital (Japan)
Hidetaka Arimura, Kyushu Univ. (Japan)
Koutarou Terashima, Kyushu Univ. Beppu Hospital (Japan)
Masakazu Hirakawa, Kyushu Univ. Beppu Hospital (Japan)
Taka-aki Hirose, Kyushu Univ. Hospital (Japan)
Junichi Fukunaga, Kyushu Univ. Hospital (Japan)
Yasuhiko Nakamura, Kyushu Univ. Hospital (Japan)


Published in SPIE Proceedings Vol. 10132:
Medical Imaging 2017: Physics of Medical Imaging
Thomas G. Flohr; Joseph Y. Lo; Taly Gilat Schmidt, Editor(s)

© SPIE. Terms of Use
Back to Top