Share Email Print
cover

Proceedings Paper

Photoacoustic measurements of red blood cell oxygen saturation in blood bags in situ
Author(s): Ruben N. Pinto; Karan Bagga; Alexandre Douplik; Jason P. Acker; Michael C. Kolios
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Red blood cell (RBC) transfusion is a critical component of the health care services. RBCs are stored in blood bags in hypothermic temperatures for a maximum of 6 weeks post donation. During this in vitro storage period, RBCs have been documented to undergo changes in structure and function due to mechanical and biochemical stress. Currently, there are no assessment methods that monitor the quality of RBCs within blood bags stored for transfusion. Conventional assessment methods require the extraction of samples, consequently voiding the sterility of the blood bags and potentially rendering them unfit for transfusions. It is hypothesized that photoacoustic (PA) technology can provide a rapid and non-invasive indication of RBC quality. In this study, a novel PA setup was developed for the acquisition of oxygen saturation (SO2) of two blood bags in situ. These measurements were taken throughout the lifespan of the blood bags (42 days) and compared against the clinical gold standard method of the blood gas analyzer (BGA). SO2 values of the blood bags increased monotonically throughout the storage period. A strong correlation between PA SO2 and BGA SO2 was found, however, PA values were on average 3.5% lower. Both techniques found the bags to increase by an SO2 of approximately 20%, and measured very similar rates of SO2 change. Future work will be focused on determining the cause of discrepancy between SO2 values acquired from PA versus BGA, as well as establishing links between the measured SO2 increase and other changes in RBC in situ.

Paper Details

Date Published: 3 March 2017
PDF: 7 pages
Proc. SPIE 10064, Photons Plus Ultrasound: Imaging and Sensing 2017, 1006440 (3 March 2017); doi: 10.1117/12.2253530
Show Author Affiliations
Ruben N. Pinto, Institute of Biomedical Engineering, Science and Technology (Canada)
Ryerson Univ. (Canada)
Karan Bagga, Institute of Biomedical Engineering, Science and Technology (Canada)
Ryerson Univ. (Canada)
Alexandre Douplik, Institute of Biomedical Engineering, Science and Technology (Canada)
Ryerson Univ. (Canada)
Jason P. Acker, Ctr. for Innovation, Canadian Blood Services (Canada)
Univ. of Alberta (Canada)
Michael C. Kolios, Institute of Biomedical Engineering, Science and Technology (Canada)
Ryerson Univ. (Canada)


Published in SPIE Proceedings Vol. 10064:
Photons Plus Ultrasound: Imaging and Sensing 2017
Alexander A. Oraevsky; Lihong V. Wang, Editor(s)

© SPIE. Terms of Use
Back to Top