Share Email Print
cover

Proceedings Paper

A three-step reconstruction method for fluorescence molecular tomography based on compressive sensing
Author(s): Yansong Zhu; Abhinav K. Jha; Jakob K. Dreyer; Hanh N. D. Le; Jin U. Kang; Per E. Roland; Dean F. Wong; Arman Rahmim
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Fluorescence molecular tomography (FMT) is a promising tool for real time in vivo quantification of neurotransmission (NT) as we pursue in our BRAIN initiative effort. However, the acquired image data are noisy and the reconstruction problem is ill-posed. Further, while spatial sparsity of the NT effects could be exploited, traditional compressive-sensing methods cannot be directly applied as the system matrix in FMT is highly coherent. To overcome these issues, we propose and assess a three-step reconstruction method. First, truncated singular value decomposition is applied on the data to reduce matrix coherence. The resultant image data are input to a homotopy-based reconstruction strategy that exploits sparsity via ℓ1 regularization. The reconstructed image is then input to a maximum-likelihood expectation maximization (MLEM) algorithm that retains the sparseness of the input estimate and improves upon the quantitation by accurate Poisson noise modeling. The proposed reconstruction method was evaluated in a three-dimensional simulated setup with fluorescent sources in a cuboidal scattering medium with optical properties simulating human brain cortex (reduced scattering coefficient: 9.2 cm−1, absorption coefficient: 0.1 cm−1 and tomographic measurements made using pixelated detectors. In different experiments, fluorescent sources of varying size and intensity were simulated. The proposed reconstruction method provided accurate estimates of the fluorescent source intensity, with a 20% lower root mean square error on average compared to the pure-homotopy method for all considered source intensities and sizes. Further, compared with conventional ℓ2 regularized algorithm, overall, the proposed method reconstructed substantially more accurate fluorescence distribution. The proposed method shows considerable promise and will be tested using more realistic simulations and experimental setups.

Paper Details

Date Published: 17 February 2017
PDF: 8 pages
Proc. SPIE 10059, Optical Tomography and Spectroscopy of Tissue XII, 1005911 (17 February 2017); doi: 10.1117/12.2252664
Show Author Affiliations
Yansong Zhu, Johns Hopkins Univ. (United States)
Abhinav K. Jha, Johns Hopkins Univ. (United States)
Jakob K. Dreyer, Univ. of Copenhagen (Denmark)
Hanh N. D. Le, Johns Hopkins Univ. (United States)
Jin U. Kang, Johns Hopkins Univ. (United States)
Per E. Roland, Univ. of Copenhagen (Denmark)
Dean F. Wong, Johns Hopkins Univ. (United States)
Arman Rahmim, Johns Hopkins Univ. (United States)


Published in SPIE Proceedings Vol. 10059:
Optical Tomography and Spectroscopy of Tissue XII
Bruce J. Tromberg; Arjun G. Yodh; Eva Marie Sevick-Muraca; Robert R. Alfano, Editor(s)

© SPIE. Terms of Use
Back to Top