Share Email Print
cover

Proceedings Paper

Temperature insensitive prediction of glucose concentration in turbid medium using multivariable calibration based on external parameter orthogonalization
Author(s): Tongshuai Han; Ziyang Zhang; Cuiying Sun; Chao Guo; Di Sun; Jin Liu
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

The measurement accuracy of non-invasive blood glucose concentration (BGC) sensing with near-infrared spectroscopy is easily affected by the temperature variation in tissue because it would induce an unacceptable spectrum variation and the consequent prediction deviation. We use a multivariable correction method based on external parameter orthogonalization (EPO) to calibrate the spectral data recorded at different temperature values to reduce the spectral variation. The tested medium is a kind of tissue phantom, the Intralipid aqueous solution. The calibration uses a projection matrix to get the orthogonal spectral space to the variable of external parameter, i.e. temperature, and then the useful spectral information relative to glucose concentration has been reserved. Even more, training the projection matrix can be separated to building the calibration matrix for the prediction of glucose concentration as it only uses the representative samples’ data with temperature variation. The method presents a lower complexity than modeling a robust prediction matrix, which can be built from comprehensive spectral data involved the all variables both of BGC and temperature. In our test, the calibrated spectra with the same glucose concentration but different temperature values show a significantly improved repeatability. And then the glucose concentration prediction results show a lower root mean squared error of prediction (RMSEP) than that using the robust calibration model, which has considered the two variables. We also discuss the rationality of the representative samples chosen by EPO. This research may be referenced to the temperature calibration for in vivo BGC sensing.

Paper Details

Date Published: 31 October 2016
PDF: 7 pages
Proc. SPIE 10024, Optics in Health Care and Biomedical Optics VII, 100242R (31 October 2016); doi: 10.1117/12.2245904
Show Author Affiliations
Tongshuai Han, Tianjin Univ. (China)
Ziyang Zhang, Tianjin Univ. (China)
Cuiying Sun, Tianjin Univ. (China)
Chao Guo, Tianjin Univ. (China)
Di Sun, Tianjin Univ. (China)
Jin Liu, Tianjin Univ. (China)


Published in SPIE Proceedings Vol. 10024:
Optics in Health Care and Biomedical Optics VII
Qingming Luo; Xingde Li; Ying Gu; Yuguo Tang, Editor(s)

© SPIE. Terms of Use
Back to Top