Optimization on source detector distance for the glucose sensing in a tissue phantom using near-infrared diffuse spectra
Author(s): Chao Guo; Tongshuai Han; Ziyang Zhang; Di Sun; Jin Liu
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

In the non-invasive blood glucose concentration (BGC) sensing, the measurement based on near infrared spectroscopy has been a promising technology since it had acquired dozens of satisfactory results in short-term glucose monitoring tests. However, it’s still necessary to improve the measurement precision because it has challenges of the reduced precision in a long-term test when a lot of variables in the test would exist. Considering the requirement of multivariable analysis, the signals of diffuse reflectance spectra should include enough absorption information from glucose. However, the sensitivity of diffuse light intensity to the absorption variation at different source detector separations (SDSs) could be different. We present an analysis method using Monte-Carlo (MC) simulation and the diffuse equation for reasonably selecting proper SDS to get a satisfactory glucose measurement precision when there are multivariable disturbances. In the case of measuring glucose in a tissue phantom using the waveband of 1000-1340 nm, we show the SDS optimization result by using this analysis method. The experiment was designed to measure the diffuse reflectance spectra at 0.1-3.0 mm with the step of 0.1 mm, and the phantom solutions with different glucose concentrations and hemoglobin concentrations are tested. The glucose prediction precision was evaluated using the root mean squared error of prediction (RMSEP) for the all SDSs of 0.1-3.0 mm, and the SDSs with the lower RMSEP were selected for use. Moreover, the selected SDSs in the experiment shows a similar conclusion from the MC simulation. This work could be referenced to the in vivo BGC measurement.

Paper Details

Date Published: 31 October 2016
PDF: 10 pages
Proc. SPIE 10024, Optics in Health Care and Biomedical Optics VII, 100242N (31 October 2016); doi: 10.1117/12.2245862
Show Author Affiliations
Chao Guo, Tianjin Univ. (China)
Tongshuai Han, Tianjin Univ. (China)
Ziyang Zhang, Tianjin Univ. (China)
Di Sun, Tianjin Univ. (China)
Jin Liu, Tianjin Univ. (China)


Published in SPIE Proceedings Vol. 10024:
Optics in Health Care and Biomedical Optics VII
Qingming Luo; Xingde Li; Ying Gu; Yuguo Tang, Editor(s)

© SPIE. Terms of Use
Back to Top