Share Email Print
cover

Proceedings Paper

The mechanical and EM simulations of the CryoAC for the ATHENA X-IFU
Author(s): D. Corsini; M. Biasotti; F. Gatti; M. De Gerone; C. Rossi; L. Piro; C. Macculi
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

The design phase of the CryoAC DM for the ATHENA X-IFU has concerned numerical simulations to exploit different fabrication possibilities. The mechanical simulations have accounted for the peculiar detector structure: 4 silicon chips asymmetrically suspended by means of 4 microbridges each. A preliminary study was performed to analyze the response to acceleration spectra in the frequency domain, shocks and time domain random displacement, prior to a real vibration test campaign. EM simulations to spot unwanted magnetic fields have been conducted as well. In this work we will show the latest advance in the design of the new detectors, showing the main results coming from various simulations.

Paper Details

Date Published: 11 July 2016
PDF: 11 pages
Proc. SPIE 9905, Space Telescopes and Instrumentation 2016: Ultraviolet to Gamma Ray, 99055Y (11 July 2016); doi: 10.1117/12.2232499
Show Author Affiliations
D. Corsini, Univ. di Genova (Italy)
INFN (Italy)
M. Biasotti, Univ. di Genova (Italy)
INFN (Italy)
F. Gatti, Univ. di Genova (Italy)
INFN (Italy)
M. De Gerone, Univ. di Genova (Italy)
INFN (Italy)
C. Rossi, INFN (Italy)
L. Piro, INAF/IAPS (Italy)
C. Macculi, INAF/IAPS (Italy)


Published in SPIE Proceedings Vol. 9905:
Space Telescopes and Instrumentation 2016: Ultraviolet to Gamma Ray
Jan-Willem A. den Herder; Tadayuki Takahashi; Marshall Bautz, Editor(s)