Share Email Print
cover

Proceedings Paper

Toward large µ-calorimeters x-ray matrices based on metal-insulator sensors and HEMTs/SiGe cryo-electronics
Author(s): J. L. Sauvageot; C. Pigot; X. de la Broïse; T. Charvolin; H. Sahin; M. Rodriguez; F. Lugiez; A. Le Coguie; Q. Dong; Y. Jin
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

The launch of ASTRO-H/ITOMI ,the X-ray Japanese/US mission, in February 2016 with μ-calorimeters based on Metal-Insulator-Sensors (M.I.S) experiment with a 4.5eV spectral resolution, would certainly generate renewed interest on the high impedance M.I.S based on Si P:B. Since 2009 we are involved in a large program to build a camera consisting of a 2x2 mosaic of 32x32 pixel matrices using this sensor type. Since we rely on very similar approach of ASTRO-H/ITOMI design, we have concentred our efforts on the use of collective all-silicon technologies only. We have already presented the building block such as thermometers, sensors and cryo-electronics. Now, thanks to our new 32x32 CAD, we are today in the process of building 4 32x32 matrices per wafer. ASTRO-H/SXS uses degenerated Si as output wiring of the pixel and an HgTe semi-conductor absorber. Thanks to the use of superconducting wiring and composite superconducting Tantalum absorber, we hope to enhance the spectral resolution of this matrix onto that of SXS. Moreover, our development benefits of an ultra low power consumption Cryo-Electronics chain. This chain is based on High Electron Mobility Transistors (HEMTs, with an AsGa/AlAsGa hetero-junction) and SiGe ASICs, and handles 34:1 multiplexing. It has been successfully tested under cryogenic conditions. The composite Tantalum absorber have been tested with 6keV X-rays, and our M.I.S. exhibit good and homogeneous sensitivity. To be compatible with the 1μW at 50mK thermal budget allowed in present day spatial cryo-coolers, we have also developed new thermal insulation techniques that will allow us to easily handle more than 4000 independent pixels within this tiny power budget.

Paper Details

Date Published: 18 July 2016
PDF: 8 pages
Proc. SPIE 9905, Space Telescopes and Instrumentation 2016: Ultraviolet to Gamma Ray, 99050S (18 July 2016); doi: 10.1117/12.2232397
Show Author Affiliations
J. L. Sauvageot, CEA-Saclay (France)
C. Pigot, CEA-Saclay (France)
X. de la Broïse, CEA-Saclay (France)
T. Charvolin, CEA-Grenoble-Minatec (France)
H. Sahin, CEA-Grenoble-Minatec (France)
M. Rodriguez, CEA, LIST (France)
F. Lugiez, CEA-Saclay (France)
A. Le Coguie, CEA-Saclay (France)
Q. Dong, CNRS/C2N (France)
Y. Jin, CNRS/C2N (France)


Published in SPIE Proceedings Vol. 9905:
Space Telescopes and Instrumentation 2016: Ultraviolet to Gamma Ray
Jan-Willem A. den Herder; Tadayuki Takahashi; Marshall Bautz, Editor(s)

© SPIE. Terms of Use
Back to Top