Share Email Print
cover

Proceedings Paper

A new paradigm of dielectric relaxation spectroscopy for non-invasive detection of breast abnormalities: a preliminary feasibility analysis
Author(s): Sreeram Dhurjaty; Yuchen Qiu; Maxine Tan; Wei Qian; Bin Zheng
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

In order to improve efficacy of screening mammography, in recent years, we have been investigating the feasibility of applying a resonance-frequency based electrical impedance spectroscopy (REIS) technology to noninvasively detect breast abnormalities that may lead to the development of cancer in the near-term. Despite promising study-results, we found that REIS suffered from relatively poor reproducibility due to perturbations in electrode placement, contact pressure variation on the breast, as well as variation of the resonating inductor. To overcome this limitation, in this study, we propose and analyze a new paradigm of Dielectric Relaxation Spectroscopy (DRS) that measures polarization-lag of dielectric signals in breast-capacitance when excited by the pulses or sine waves. Unlike conventional DRS that operates using the signals at very high frequencies (GHz) to examine changes in polarization, our new method detects and characterizes the dielectric properties of tissue at low frequencies (≤10 MHz) due to the advent of inexpensive oscillators that are accurate to 1 pico-second (used in GPS receivers) as well as measurement of amplitudes of 1 ppm or better. From theoretical analysis, we have proved that the sensitivity of new DRS in detecting permittivity of water increased by ≥80 times as compared to conventional DRS, which operates at frequencies around 4GHz. By analyzing and comparing the relationship between the new DRS and REIS, we found that this DRS has potential advantages in enhancing repeatability from various readings, including temperature-insensitive detection, and yielding higher resolution or sensitivity (up to 100 Femtofarads).

Paper Details

Date Published: 29 March 2016
PDF: 7 pages
Proc. SPIE 9783, Medical Imaging 2016: Physics of Medical Imaging, 97832P (29 March 2016); doi: 10.1117/12.2217196
Show Author Affiliations
Sreeram Dhurjaty, Dhurjaty Electronics Consulting LLC (United States)
Yuchen Qiu, The Univ. of Oklahoma (United States)
Maxine Tan, The Univ. of Oklahoma (United States)
Wei Qian, The Univ. of Texas at El Paso (United States)
Bin Zheng, The Univ. of Oklahoma (United States)


Published in SPIE Proceedings Vol. 9783:
Medical Imaging 2016: Physics of Medical Imaging
Despina Kontos; Thomas G. Flohr, Editor(s)

© SPIE. Terms of Use