Share Email Print
cover

Proceedings Paper

Spatio-energetic cross-talks in photon counting detectors: detector model and correlated Poisson data generator
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

An x-ray photon interacts with photon counting detectors (PCDs) and generates an electron charge cloud or multiple clouds. The clouds (thus, the photon energy) may be split between two adjacent PCD pixels when the interaction occurs near pixel boundaries, producing a count at both of the two pixels. This is called double-counting with charge sharing. The output of individual PCD pixel is Poisson distributed integer counts; however, the outputs of adjacent pixels are correlated due to double-counting. Major problems are the lack of detector noise model for the spatio-energetic crosstalk and the lack of an efficient simulation tool. Monte Carlo simulation can accurately simulate these phenomena and produce noisy data; however, it is not computationally efficient. In this study, we developed a new detector model and implemented into an efficient software simulator which uses a Poisson random number generator to produce correlated noisy integer counts. The detector model takes the following effects into account effects: (1) detection efficiency and incomplete charge collection; (2) photoelectric effect with total absorption; (3) photoelectric effect with fluorescence x-ray emission and re-absorption; (4) photoelectric effect with fluorescence x-ray emission which leaves PCD completely; and (5) electric noise. The model produced total detector spectrum similar to previous MC simulation data. The model can be used to predict spectrum and correlation with various different settings. The simulated noisy data demonstrated the expected performance: (a) data were integers; (b) the mean and covariance matrix was close to the target values; (c) noisy data generation was very efficient

Paper Details

Date Published: 25 March 2016
PDF: 9 pages
Proc. SPIE 9783, Medical Imaging 2016: Physics of Medical Imaging, 97831R (25 March 2016); doi: 10.1117/12.2217133
Show Author Affiliations
Katsuyuki Taguchi, Johns Hopkins Univ. School of Medicine (United States)
Christoph Polster, Ludwig-Maximilians-Univ. Hospital (Germany)
Siemens Healthcare GmbH (Germany)
Okkyun Lee, Johns Hopkins Univ. School of Medicine (United States)
Steffen Kappler, Siemens Healthcare GmbH (Germany)


Published in SPIE Proceedings Vol. 9783:
Medical Imaging 2016: Physics of Medical Imaging
Despina Kontos; Thomas G. Flohr, Editor(s)

© SPIE. Terms of Use
Back to Top