Share Email Print
cover

Proceedings Paper

Regularization design for high-quality cone-beam CT of intracranial hemorrhage using statistical reconstruction
Author(s): H. Dang; J. W. Stayman; J. Xu; A. Sisniega; W. Zbijewski; X. Wang; D. H. Foos; N. Aygun; V. E. Koliatsos; J. H. Siewerdsen
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Intracranial hemorrhage (ICH) is associated with pathologies such as hemorrhagic stroke and traumatic brain injury. Multi-detector CT is the current front-line imaging modality for detecting ICH (fresh blood contrast 40-80 HU, down to 1 mm). Flat-panel detector (FPD) cone-beam CT (CBCT) offers a potential alternative with a smaller scanner footprint, greater portability, and lower cost potentially well suited to deployment at the point of care outside standard diagnostic radiology and emergency room settings. Previous studies have suggested reliable detection of ICH down to 3 mm in CBCT using high-fidelity artifact correction and penalized weighted least-squared (PWLS) image reconstruction with a post-artifact-correction noise model. However, ICH reconstructed by traditional image regularization exhibits nonuniform spatial resolution and noise due to interaction between the statistical weights and regularization, which potentially degrades the detectability of ICH. In this work, we propose three regularization methods designed to overcome these challenges. The first two compute spatially varying certainty for uniform spatial resolution and noise, respectively. The third computes spatially varying regularization strength to achieve uniform "detectability," combining both spatial resolution and noise in a manner analogous to a delta-function detection task. Experiments were conducted on a CBCT test-bench, and image quality was evaluated for simulated ICH in different regions of an anthropomorphic head. The first two methods improved the uniformity in spatial resolution and noise compared to traditional regularization. The third exhibited the highest uniformity in detectability among all methods and best overall image quality. The proposed regularization provides a valuable means to achieve uniform image quality in CBCT of ICH and is being incorporated in a CBCT prototype for ICH imaging.

Paper Details

Date Published: 31 March 2016
PDF: 8 pages
Proc. SPIE 9783, Medical Imaging 2016: Physics of Medical Imaging, 97832Y (31 March 2016); doi: 10.1117/12.2216937
Show Author Affiliations
H. Dang, Johns Hopkins Univ. (United States)
J. W. Stayman, Johns Hopkins Univ. (United States)
J. Xu, Johns Hopkins Univ. (United States)
A. Sisniega, Johns Hopkins Univ. (United States)
W. Zbijewski, Johns Hopkins Univ. (United States)
X. Wang, Carestream Health, Inc. (United States)
D. H. Foos, Carestream Health, Inc. (United States)
N. Aygun, Johns Hopkins Univ. (United States)
V. E. Koliatsos, Johns Hopkins Univ. (United States)
J. H. Siewerdsen, Johns Hopkins Univ. (United States)


Published in SPIE Proceedings Vol. 9783:
Medical Imaging 2016: Physics of Medical Imaging
Despina Kontos; Thomas G. Flohr, Editor(s)

© SPIE. Terms of Use
Back to Top