Novel automatic detection of pleura and B-lines (comet-tail artifacts) on in vivo lung ultrasound scans
Author(s): Ramin Moshavegh; Kristoffer Lindskov Hansen; Hasse Møller Sørensen; Martin Christian Hemmsen; Caroline Ewertsen; Michael Bachmann Nielsen; Jørgen Arendt Jensen
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

This paper presents a novel automatic method for detection of B-lines (comet-tail artifacts) in lung ultrasound scans. B-lines are the most commonly used artifacts for analyzing the pulmonary edema. They appear as laser-like vertical beams, which arise from the pleural line and spread down without fading to the edge of the screen. An increase in their number is associated with presence of edema. All the scans used in this study were acquired using a BK3000 ultrasound scanner (BK Ultrasound, Denmark) driving a 192-element 5:5 MHz wide linear transducer (10L2W, BK Ultrasound). The dynamic received focus technique was employed to generate the sequences. Six subjects, among those three patients after major surgery and three normal subjects, were scanned once and Six ultrasound sequences each containing 50 frames were acquired. The proposed algorithm was applied to all 300 in-vivo lung ultrasound images. The pleural line is first segmented on each image and then the B-line artifacts spreading down from the pleural line are detected and overlayed on the image. The resulting 300 images showed that the mean lateral distance between B-lines detected on images acquired from patients decreased by 20% in compare with that of normal subjects. Therefore, the method can be used as the basis of a method of automatically and qualitatively characterizing the distribution of B-lines.

Paper Details

Date Published: 1 April 2016
PDF: 7 pages
Proc. SPIE 9790, Medical Imaging 2016: Ultrasonic Imaging and Tomography, 97900K (1 April 2016); doi: 10.1117/12.2216499
Show Author Affiliations
Ramin Moshavegh, Technical Univ. of Denmark (Denmark)
Kristoffer Lindskov Hansen, Copenhagen Univ. Hospital (Denmark)
Hasse Møller Sørensen, Copenhagen Univ. Hospital (Denmark)
Martin Christian Hemmsen, Technical Univ. of Denmark (Denmark)
Caroline Ewertsen, Copenhagen Univ. Hospital (Denmark)
Michael Bachmann Nielsen, Copenhagen Univ. Hospital (Denmark)
Jørgen Arendt Jensen, Technical Univ. of Denmark (Denmark)


Published in SPIE Proceedings Vol. 9790:
Medical Imaging 2016: Ultrasonic Imaging and Tomography
Neb Duric; Brecht Heyde, Editor(s)

© SPIE. Terms of Use
Back to Top