Share Email Print
cover

Proceedings Paper

Application of optical coherence interferometry to measure the spatial profile of fluid flow velocity
Author(s): Xiao-jun Wang; Thomas E. Milner; J. Stuart Nelson
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

The spatial profile of fluid flow velocity in transparent glass conduits is measured using optical Doppler tomography (ODT). The flow velocity at any spatial location in the conduits is determined by measuring the Doppler shift of backscattered light from moving microspheres in the fluid. ODT is an accurate and inexpensive method for high resolution characterization of fluid flow velocity profile.

Paper Details

Date Published: 29 September 1995
PDF: 6 pages
Proc. SPIE 2546, Optical Techniques in Fluid, Thermal, and Combustion Flow, (29 September 1995); doi: 10.1117/12.221538
Show Author Affiliations
Xiao-jun Wang, Beckman Laser Institute and Medical Clinic (United States)
Thomas E. Milner, Beckman Laser Institute and Medical Clinic (United States)
J. Stuart Nelson, Beckman Laser Institute and Medical Clinic (United States)


Published in SPIE Proceedings Vol. 2546:
Optical Techniques in Fluid, Thermal, and Combustion Flow
Soyoung Stephen Cha; James D. Trolinger, Editor(s)

© SPIE. Terms of Use