Approaches on calibration of bolometer and establishment of bolometer calibration device
Author(s): Ming Xia; Jianqiang Gao; Jun'an Ye; Junwen Xia; Dejin Yin; Tiecheng Li; Dong Zhang
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Bolometer is mainly used for measuring thermal radiation in the field of public places, labor hygiene, heating and ventilation and building energy conservation. The working principle of bolometer is under the exposure of thermal radiation, temperature of black absorbing layer of detector rise after absorption of thermal radiation, which makes the electromotive force produced by thermoelectric. The white light reflective layer of detector does not absorb thermal radiation, so the electromotive force produced by thermoelectric is almost zero. A comparison of electromotive force produced by thermoelectric of black absorbing layer and white reflective layer can eliminate the influence of electric potential produced by the basal background temperature change. After the electromotive force which produced by thermal radiation is processed by the signal processing unit, the indication displays through the indication display unit. The measurement unit of thermal radiation intensity is usually W/m2 or kW/m2. Its accurate and reliable value has important significance for high temperature operation, labor safety and hygiene grading management. Bolometer calibration device is mainly composed of absolute radiometer, the reference light source, electric measuring instrument. Absolute radiometer is a self-calibration type radiometer. Its working principle is using the electric power which can be accurately measured replaces radiation power to absolutely measure the radiation power. Absolute radiometer is the standard apparatus of laser low power standard device, the measurement traceability is guaranteed. Using the calibration method of comparison, the absolute radiometer and bolometer measure the reference light source in the same position alternately which can get correction factor of irradiance indication. This paper is mainly about the design and calibration method of the bolometer calibration device. The uncertainty of the calibration result is also evaluated.

Paper Details

Date Published: 8 October 2015
PDF: 5 pages
Proc. SPIE 9677, AOPC 2015: Optical Test, Measurement, and Equipment, 96771H (8 October 2015); doi: 10.1117/12.2199684
Show Author Affiliations
Ming Xia, Shanghai Institute of Measurement and Testing Technology (China)
Jianqiang Gao, Shanghai Institute of Measurement and Testing Technology (China)
Jun'an Ye, Shanghai Institute of Measurement and Testing Technology (China)
Junwen Xia, Shanghai Institute of Measurement and Testing Technology (China)
Dejin Yin, Shanghai Institute of Measurement and Testing Technology (China)
Tiecheng Li, Shanghai Institute of Measurement and Testing Technology (China)
Dong Zhang, Shanghai Institute of Measurement and Testing Technology (China)


Published in SPIE Proceedings Vol. 9677:
AOPC 2015: Optical Test, Measurement, and Equipment
Sen Han; Jonathan D. Ellis; Junpeng Guo; Yongcai Guo, Editor(s)

© SPIE. Terms of Use
Back to Top