Share Email Print
cover

Proceedings Paper

Recent advances in Er3+:YAG solid-state heat-capacity technology
Author(s): Stefano Bigotta; Karsten Diener; Thierry Ibach; Lothar Geiss; Georg Stöppler; Jörg Schöner; Michael von Salisch; Marc Eichhorn
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

The Er3+:YAG Solid State Heat-Capacity Laser (SSHCL) as a source for medium and high energy laser systems in the “eye-safe” range is currently under investigation at ISL. The aim is to obtain a robust laser source with low complexity, high beam quality (M2 < 3) and scalable to 100 kW and beyond. In a SSHCL the laser medium is cooled only after the laser action has ended, resulting in low temperature gradients in the laser medium itself during operation. Previous investigations demonstrated the scalability of the SSHCL and up to 4.65 kW and 440 J in less than 800 ms have been achieved. Optical-to-optical efficiencies of more than 41% and slope efficiencies of over 51% has been obtained. The residual thermal gradients, due to non perfect pumping homogeneity, negatively affect the performance in terms of laser pulse energy, duration and beam quality. Using an intra-cavity adaptive optics system, beam aberrations were limited to less than 1/10 of the wavelength for each of the considered Zernike polynomials, and the shot duration lengthened by about 50%. In this paper we investigate how to further increase the SSHCL pulse duration. The influence of the crystal geometry on the pump distribution homogeneity and the pulse duration are analysed. We consider the use of a mechanical crystal changer for extending the laser pulse duration. By using a revolver with several crystals, we demonstrated that crystals can be correctly positioned in less than 100 ms, allowing a quasi-cw operation that can largely exceed the time constraints imposed by the heating of the crystal. Finally, we address the problem of measuring the laser beam quality. Since the current standard techniques are suitable only for stable cw lasers, they cannot be used for the SSHCL. A new kind of device, capable of measuring the M2 at intervals of less than 100 ms, is presented.

Paper Details

Date Published: 27 October 2015
PDF: 13 pages
Proc. SPIE 9650, Technologies for Optical Countermeasures XII; and High-Power Lasers 2015: Technology and Systems, 965002 (27 October 2015); doi: 10.1117/12.2197681
Show Author Affiliations
Stefano Bigotta, Institut Franco-Allemand de Recherches de Saint-Louis (France)
Karsten Diener, Institut Franco-Allemand de Recherches de Saint-Louis (France)
Thierry Ibach, Institut Franco-Allemand de Recherches de Saint-Louis (France)
Lothar Geiss, Institut Franco-Allemand de Recherches de Saint-Louis (France)
Georg Stöppler, Institut Franco-Allemand de Recherches de Saint-Louis (France)
Jörg Schöner, Institut Franco-Allemand de Recherches de Saint-Louis (France)
Michael von Salisch, Institut Franco-Allemand de Recherches de Saint-Louis (France)
Marc Eichhorn, Institut Franco-Allemand de Recherches de Saint-Louis (France)


Published in SPIE Proceedings Vol. 9650:
Technologies for Optical Countermeasures XII; and High-Power Lasers 2015: Technology and Systems
David H. Titterton; Harro Ackermann; Willy L. Bohn; Robert J. Grasso; Mark A. Richardson, Editor(s)

© SPIE. Terms of Use
Back to Top