High performance x-ray imaging detectors on foil using solution-processed organic photodiodes with extremely low dark leakage current (Presentation Recording)
Author(s): Abhishek Kumar; Date Moet; Jan Laurens van der Steen; Albert van Breemen; Santhosh Shanmugam; Jan Gilot; Ronn Andriessen; Matthias Simon; Walter Ruetten; Alexander Douglas; Rob Raaijmakers; Pawel E. Malinowski; Kris Myny; Gerwin Gelinck
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

High performance X-ray imaging detectors on foil using solution-processed organic photodiodes with extremely low dark leakage current Abhishek Kumara, Date Moeta, Albert van Breemena, Santhosh Shanmugama, Jan-Laurens van der Steena, Jan Gilota, Ronn Andriessena, Matthias Simonb, Walter Ruettenb, Alexander U. Douglasb, Rob Raaijmakersc, Pawel E. Malinowskid, Kris Mynyd and Gerwin H. Gelincka,e a. Holst Centre/TNO, High Tech Campus 31, Eindhoven 5656 AE, The Netherlands b. Philips Research, High Tech Campus 34, 5656 AE Eindhoven, The Netherlands c. Philips Healthcare, Veenpluis 6-8, 5684 PC Best, The Netherlands d. Department of Large Area Electronics, imec vzw, Kapeldreef 75, Leuven B3001, Belgium e. Applied Physics Department, TU Eindhoven, Eindhoven, The Netherlands We demonstrate high performance X-ray imaging detectors on foil suitable for medical grade X-ray imaging applications. The detectors are based on solution-processed organic photodiodes forming bulk-heterojunctions from photovoltaic donor and acceptor blend. The organic photodiodes are deposited using an industrially compatible slot die coating technique with end of line processing temperature below 100°C. These photodiodes have extremely low dark leakage current density of 10-7 mA/cm2 at -2V bias with very high yield and have peak absorption around 550 nm wavelength. We combine these organic photodiodes with high mobility metal oxide semiconductor based thin film transistor arrays with high pixel resolution of 200ppi on thin plastic substrate. When combined with a typical CsI(TI) scintillator material on top, they are well suited for low dose X-ray imaging applications. The optical crosstalk is insignificant upto resolution of 200 ppi despite the fact that the photodiode layer is one continuous layer and is non-pixelated. Low processing temperatures are another key advantage since they can be fabricated on plastic substrate. This implies that we can make X-ray detectors on flexible foil. Those detectors can be mechanically more robust and light weight when compared to amorphous Si based detectors fabricated on glass substrate.

Paper Details

Date Published:
PDF: 1 pages
Proc. SPIE 9567, Organic Photovoltaics XVI, 95670U; doi: 10.1117/12.2187041
Show Author Affiliations
Abhishek Kumar, Holst Ctr. (Netherlands)
Date Moet, Holst Ctr. (Netherlands)
Jan Laurens van der Steen, Holst Ctr. (Netherlands)
Albert van Breemen, Holst Ctr. (Netherlands)
Santhosh Shanmugam, Holst Ctr. (Netherlands)
Jan Gilot, Holst Ctr. (Netherlands)
Ronn Andriessen, Holst Ctr. (Netherlands)
Matthias Simon, Philips Research (Netherlands)
Walter Ruetten, Philips Research (Netherlands)
Alexander Douglas, Philips Research (Netherlands)
Rob Raaijmakers, Philips Healthcare (Netherlands)
Pawel E. Malinowski, IMEC (Belgium)
Kris Myny, IMEC (Belgium)
Gerwin Gelinck, Holst Ctr. (Netherlands)
Technische Univ. Eindhoven (Netherlands)


Published in SPIE Proceedings Vol. 9567:
Organic Photovoltaics XVI
Zakya H. Kafafi; Paul A. Lane; Ifor D. W. Samuel, Editor(s)

Video Presentation

High-performance-x-ray-imaging-detectors-on-foil-using-solution



© SPIE. Terms of Use
Back to Top