New interferometric method for measuring refractive index distribution in wedge-shaped GRIN blanks
Author(s): Ludmila A. Gerasimova
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

A new interferometric method for measuring refractive index distribution in GRIN blanks with shapes deviating from plane-parallel ones is described. It uses a standard double-pass interferometric scheme modified to provide single passing of the beam through the investigated GRIN sample. Four interferograms recorded with one preliminary adjustment of the sample allow to restore the distribution of refractive index in the sample, eliminating errors introduced by imperfectness of the interferometer and of sample surfaces, and wedge shape of the sample. The method does not need information about the thickness and the wedge angle of a blank. Two-dimensional dependence of refractive index in transverse dimensions along the sample surface can be measured with the accuracy better than 1(DOT)10-4.

Paper Details

Date Published: 11 August 1995
PDF: 7 pages
Proc. SPIE 2537, Novel Optical Systems Design and Optimization, (11 August 1995); doi: 10.1117/12.216393
Show Author Affiliations
Ludmila A. Gerasimova, St. Petersburg Institute of Fine Mechanics and Optics (Russia)