Monitoring of the quality of side-firing fibers using a special design power meter: Aquarius
Author(s): Christiaan F. P. van Swol; Rudolf M. Verdaasdonck; Fidel A. Hermans; Remco J. van Vliet; Tom A. Boon
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

The treatment of Benign Prostatic Hyperplasia using the Nd:YAG laser is developing rapidly since the clinical introduction three years ago. In most cases a right angled fiber is used to deliver the laser light laterally towards the abundant prostatic tissue. The characteristics of these fibers differ, with regard to the angle at which the beam exits the fiber and the beam profile, resulting in a specific power density distribution on the tissue. During clinical use the characteristics of a fiber may change due to deterioration of the fiber tip. In this study the behavior of the various devices was monitored before and during clinical use with a special design power meter (Aquarius). The Aquarius measures the status of a right angled fiber in about fifteen seconds under clinical conditions, i.e., under water and at high input powers (40 - 80 Watt). In contrast with integrating sphere power meters specifically the primary beam is measured. The degree of deterioration of various fibers was quantified optically and thermally during clinical use. Devices using a metal mirror transmitted slightly less power than internal refraction based devices (80 versus 90 percent). The transmission of the various devices was not linear with the input power; at higher input powers (> 30 Watts) vapor bubbles, that developed at the tip of the device, decreased the transmission. During clinical use there was a large variation in decrease of transmission with regard to the total amount of energy transmitted through the fiber. However, at the end of a procedure the transmission had dropped to under 50%. The Aquarius is a powerful tool for evaluation and comparison of different laser prostatectomy devices both for clinical and experimental studies.

Paper Details

Date Published: 12 May 1995
PDF: 6 pages
Proc. SPIE 2395, Lasers in Surgery: Advanced Characterization, Therapeutics, and Systems V, (12 May 1995); doi: 10.1117/12.209057
Show Author Affiliations
Christiaan F. P. van Swol, Univ. Hospital Utrecht (Netherlands)
Rudolf M. Verdaasdonck, Univ. Hospital Utrecht (Netherlands)
Fidel A. Hermans, Univ. Hospital Utrecht (Netherlands)
Remco J. van Vliet, Univ. Hospital Utrecht (Netherlands)
Tom A. Boon, Univ. Hospital Utrecht (Netherlands)


Published in SPIE Proceedings Vol. 2395:
Lasers in Surgery: Advanced Characterization, Therapeutics, and Systems V
R. Rox Anderson; Graham M. Watson; Rudolf W. Steiner; Douglas E. Johnson; Stanley M. Shapshay; Michail M. Pankratov; George S. Abela; Lawrence S. Bass; John V. White; Rodney A. White; Kenneth Eugene Bartels; Lloyd P. Tate; C. Thomas Vangsness, Editor(s)

© SPIE. Terms of Use
Back to Top