Multi-helical ultrasonic imaging for corrosion monitoring of cylindrical structures
Author(s): Brennan Dubuc; Ehsan Dehghan Niri; Salvatore Salamone
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

In this paper an algorithm for acoustic emission source localization in cylindrical shell structures is presented. The proposed algorithm is based on the propagation of uncertainty through the Unscented Transform. Time of arrival of desired wave modes and wave velocity are measured parameters, whose uncertainties are processed through the algorithm, which provides mean and covariance statistics for the predicted location. Results of the algorithm using the Unscented Transform are compared to a Monte Carlo simulation, and this is accomplished through the Kullback-Leibler divergence. The results support a strong correlation between the two, however, the Unscented Transform demonstrates superior computational speed.

Paper Details

Date Published: 23 March 2015
PDF: 10 pages
Proc. SPIE 9438, Health Monitoring of Structural and Biological Systems 2015, 943803 (23 March 2015); doi: 10.1117/12.2084037
Show Author Affiliations
Brennan Dubuc, Univ. of New York at Buffalo (United States)
Ehsan Dehghan Niri, Univ. of New York at Buffalo (United States)
Salvatore Salamone, Univ. of New York at Buffalo (United States)


Published in SPIE Proceedings Vol. 9438:
Health Monitoring of Structural and Biological Systems 2015
Tribikram Kundu, Editor(s)

© SPIE. Terms of Use