Share Email Print
cover

Proceedings Paper

Needle detection in ultrasound using the spectral properties of the displacement field: a feasibility study
Author(s): Parmida Beigi; Tim Salcudean; Robert Rohling; Victoria A. Lessoway; Gary C. Ng
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

This paper presents a new needle detection technique for ultrasound guided interventions based on the spectral properties of small displacements arising from hand tremour or intentional motion. In a block-based approach, the displacement map is computed for each block of interest versus a reference frame, using an optical flow technique. To compute the flow parameters, the Lucas-Kanade approach is used in a multiresolution and regularized form. A least-squares fit is used to estimate the flow parameters from the overdetermined system of spatial and temporal gradients. Lateral and axial components of the displacement are obtained for each block of interest at consecutive frames. Magnitude-squared spectral coherency is derived between the median displacements of the reference block and each block of interest, to determine the spectral correlation. In vivo images were obtained from the tissue near the abdominal aorta to capture the extreme intrinsic body motion and insertion images were captured from a tissue-mimicking agar phantom. According to the analysis, both the involuntary and intentional movement of the needle produces coherent displacement with respect to a reference window near the insertion site. Intrinsic body motion also produces coherent displacement with respect to a reference window in the tissue; however, the coherency spectra of intrinsic and needle motion are distinguishable spectrally. Blocks with high spectral coherency at high frequencies are selected, estimating a channel for needle trajectory. The needle trajectory is detected from locally thresholded absolute displacement map within the initial estimate. Experimental results show the RMS localization accuracy of 1:0 mm, 0:7 mm, and 0:5 mm for hand tremour, vibrational and rotational needle movements, respectively.

Paper Details

Date Published: 18 March 2015
PDF: 6 pages
Proc. SPIE 9415, Medical Imaging 2015: Image-Guided Procedures, Robotic Interventions, and Modeling, 94150U (18 March 2015); doi: 10.1117/12.2081723
Show Author Affiliations
Parmida Beigi, The Univ. of British Columbia (Canada)
Tim Salcudean, The Univ. of British Columbia (Canada)
Robert Rohling, The Univ. of British Columbia (Canada)
Victoria A. Lessoway, BC Women’s Hospital (Canada)
Gary C. Ng, Philips Ultrasound (United States)


Published in SPIE Proceedings Vol. 9415:
Medical Imaging 2015: Image-Guided Procedures, Robotic Interventions, and Modeling
Robert J. Webster; Ziv R. Yaniv, Editor(s)

© SPIE. Terms of Use
Back to Top