Share Email Print
cover

Proceedings Paper

Multi-point radiometric calibration method based on complex spectrum of Fourier transform spectrometer
Author(s): Qian He; Guangping Wang; Jingli Wu; Junwei Li
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

As the impact of the instrument internal error, external interference and other factors, the interferogram measured by Fourier transform spectrometer is asymmetric, result in the complex outcome after Fourier transform. Currently, most radiometric calibration method used for Fourier transform spectrometer is usually based on real spectrums, which is converted from the above complex spectrum by calculating magnitude value or make the phase correction first. Proceed from error sources and mechanisms of the Fourier transform spectrometer, we propose a multi-point radiometric calibration method based on complex spectral data to improve the processing efficiency and accuracy, which is obtained by the original interferogram via Fourier transform. We solving the instrument response function include linear gain and offset by complex spectrum above to calculate complex spectral radiance. Compared with the traditional method based on real spectrum, the present efficient method does not limited to real spectrum and the phase correction is not required. In this paper, we use BOMEM's MR304 Fourier transform infrared spectrometer and the DCN1000N3 blackbody made by HGH Infrared Systems to carry out the radiation calibration experiment in laboratory. The results show that, the amplitude of complex radiance spectrum obtained by this method has a high consistency with the theoretical value, while the extra imaginary spectrum is similar with the difference between results and theoretical value in absolute value and trends. It proved that, this multi-point radiometric calibration method by using the amplitude of complex spectral data is highly reliable; meanwhile, the imaginary spectrum can reflect the calibration error very well and offer a new technical approach for accuracy evaluation research.

Paper Details

Date Published: 18 November 2014
PDF: 6 pages
Proc. SPIE 9298, International Symposium on Optoelectronic Technology and Application 2014: Imaging Spectroscopy; and Telescopes and Large Optics, 929805 (18 November 2014); doi: 10.1117/12.2066829
Show Author Affiliations
Qian He, Science and Technology on Optical Radiation Lab. (China)
Guangping Wang, Science and Technology on Optical Radiation Lab. (China)
Jingli Wu, Science and Technology on Optical Radiation Lab. (China)
Junwei Li, Science and Technology on Optical Radiation Lab. (China)


Published in SPIE Proceedings Vol. 9298:
International Symposium on Optoelectronic Technology and Application 2014: Imaging Spectroscopy; and Telescopes and Large Optics
Jannick P. Rolland; Changxiang Yan; Dae Wook Kim; Wenli Ma; Ligong Zheng, Editor(s)

© SPIE. Terms of Use
Back to Top