Share Email Print
cover

Proceedings Paper

The stability of color discrimination threshold determined using pseudoisochromatic test plates
Author(s): B. Zutere; K. Jurasevska Luse; A. Livzane
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Congenital red-green color vision deficiency is one of the most common genetic disorders. A previously printed set of pseudoisochromatic plates (KAMS test, 2012) was created for individual discrimination threshold determination in case of mild congenital red-green color vision deficiency using neutral colors (colors confused with gray). The diagnostics of color blind subjects was performed with Richmond HRR (4th edition, 2002) test, Oculus HMC anomaloscope, and further the examination was made using the KAMS test. 4 male subjects aged 20 to 24 years old participated in the study: all of them were diagnosed with deuteranomalia. Due to the design of the plates, the threshold of every subject in each trial was defined as the plate total color difference value ΔE at which the stimulus was detected 75% of the time, so the just-noticeable difference (jnd) was calculated in CIE LAB DeltaE (ΔE) units. Authors performed repeated discrimination threshold measurements (5 times) for all four subjects under controlled illumination conditions. Psychophysical data were taken by sampling an observer’s performance on a psychophysical task at a number of different stimulus saturation levels. Results show that a total color difference value ΔE threshold exists for each individual tested with the KAMS pseudoisochromatic plates, this threshold value does not change significantly in multiple measurements. Deuteranomal threshold values aquired using greenish plates of KAMS test are significantly higher than thresholds acquired using reddish plates. A strong positive correlation (R=0.94) exists between anomaloscope matching range (MR) and deuteranomal thresholds aquired by the KAMS test and (R=0.81) between error score in the Richmond HRR test and thresholds aquired by the KAMS test.

Paper Details

Date Published: 19 September 2014
PDF: 7 pages
Proc. SPIE 9216, Optics and Photonics for Information Processing VIII, 92161G (19 September 2014); doi: 10.1117/12.2061748
Show Author Affiliations
B. Zutere, Univ. of Latvia (Latvia)
K. Jurasevska Luse, Univ. of Latvia (Latvia)
A. Livzane, Univ. of Latvia (Latvia)


Published in SPIE Proceedings Vol. 9216:
Optics and Photonics for Information Processing VIII
Abdul A. S. Awwal; Khan M. Iftekharuddin; Mohammad A. Matin; Andrés Márquez, Editor(s)

© SPIE. Terms of Use
Back to Top