Paper Abstract

A closed-loop flowing basic hydrogen peroxide (BHP) system with real-time cooling was constructed and coupled to a supersonic COIL, resulting in a 20-min. continuous run at an average power of 500 W. An overall BHP heat transfer coefficient of 150 BTU/(hr(DOT)ft2(DOT) degree(s)F) was measured.