Measurement of imaging properties of scintillating fiber optic plate
Author(s): George Zentai; Arundhuti Ganguly; Josh Star-Lack; Gary Virshup; Hayley Hirsh; Daniel Shedlock; David Humber
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Scintillating Fiber Optic Plates (SFOP) or Fiber Optic Scintillator (FOS) made with scintillating fiber-glass, were investigated for x-ray imaging. Two different samples (T x W x L = 2cm x 5cm x 5cm) were used; Sample A: 10μm fibers, Sample B: 50μm fibers both with statistically randomized light absorbing fibers placed in the matrix. A customized holder was used to place the samples in close contact with photodiodes in an amorphous silicon flat panel detector (AS1000, Varian), typically used for portal imaging. The detector has a 392μm pixel pitch and in the standard configuration uses a gadolinium oxy-sulphide (GOS) screen behind a copper plate. X-ray measurements were performed at 120kV (RQA 9 spectrum), 1MeV (5mm Al filtration) and 6MeV (Flattening Filter Free) for Sample A and the latter 2 spectra for Sample B. A machined edge was used for MTF measurements. The measurements showed the MTF degraded with increased X-ray energies because of the increase in Compton scattering. However, at the Nyquist frequency of 1.3lp/mm, the MTF is still high (FOS value vs. Cu+GOS): (a) 37% and 21% at 120kVp for the 10μm FOS and the Cu+GOS arrays, (b) 31%, 20% and 20% at 1MeV and (c) 17%, 11% and 14% at 6MeV for the 10μm FOS, 50μm FOS and the Cu+GOS arrays. The DQE(0) value comparison were (a) at 120kV ~24% and ~13 % for the 10μm FOS and the Cu+GOS arrays (b) at 1MV 10%, 10% and 7% and (c) at 6MV 12%, ~19% and 1.6% for the 10μm FOS , 50μm FOS and Cu+GOS arrays.

Paper Details

Date Published: 19 March 2014
PDF: 6 pages
Proc. SPIE 9033, Medical Imaging 2014: Physics of Medical Imaging, 90333Q (19 March 2014); doi: 10.1117/12.2043887
Show Author Affiliations
George Zentai, Varian Medical Systems, Inc. (United States)
Arundhuti Ganguly, Varian Medical Systems, Inc. (United States)
Josh Star-Lack, Varian Medical Systems, Inc. (United States)
Gary Virshup, Varian Medical Systems, Inc. (United States)
Hayley Hirsh, Varian Medical Systems (United States)
Daniel Shedlock, Varian Medical Systems, Inc. (United States)
David Humber, Varian Medical Systems, Inc. (United States)


Published in SPIE Proceedings Vol. 9033:
Medical Imaging 2014: Physics of Medical Imaging
Bruce R. Whiting; Christoph Hoeschen, Editor(s)

© SPIE. Terms of Use
Back to Top