Share Email Print
cover

Proceedings Paper

Image to physical space registration of supine breast MRI for image guided breast surgery
Author(s): Rebekah H. Conley; Ingrid M. Meszoely; Thomas S. Pheiffer; Jared A. Weis; Thomas E. Yankeelov; Michael I. Miga
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Breast conservation therapy (BCT) is a desirable option for many women diagnosed with early stage breast cancer and involves a lumpectomy followed by radiotherapy. However, approximately 50% of eligible women will elect for mastectomy over BCT despite equal survival benefit (provided margins of excised tissue are cancer free) due to uncertainty in outcome with regards to complete excision of cancerous cells, risk of local recurrence, and cosmesis. Determining surgical margins intraoperatively is difficult and achieving negative margins is not as robust as it needs to be, resulting in high re-operation rates and often mastectomy. Magnetic resonance images (MRI) can provide detailed information about tumor margin extents, however diagnostic images are acquired in a fundamentally different patient presentation than that used in surgery. Therefore, the high quality diagnostic MRIs taken in the prone position with pendant breast are not optimal for use in surgical planning/guidance due to the drastic shape change between preoperative images and the common supine surgical position. This work proposes to investigate the value of supine MRI in an effort to localize tumors intraoperatively using image-guidance. Mock intraoperative setups (realistic patient positioning in non-sterile environment) and preoperative imaging data were collected from a patient scheduled for a lumpectomy. The mock intraoperative data included a tracked laser range scan of the patient's breast surface, tracked center points of MR visible fiducials on the patient's breast, and tracked B-mode ultrasound and strain images. The preoperative data included a supine MRI with visible fiducial markers. Fiducial markers localized in the MRI were rigidly registered to their mock intraoperative counterparts using an optically tracked stylus. The root mean square (RMS) fiducial registration error using the tracked markers was 3.4mm. Following registration, the average closest point distance between the MR generated surface nodes and the LRS point cloud was 1.76±0.502 mm.

Paper Details

Date Published: 12 March 2014
PDF: 8 pages
Proc. SPIE 9036, Medical Imaging 2014: Image-Guided Procedures, Robotic Interventions, and Modeling, 90362N (12 March 2014); doi: 10.1117/12.2043817
Show Author Affiliations
Rebekah H. Conley, Vanderbilt Univ. (United States)
Ingrid M. Meszoely, Vanderbilt Univ. Medical Ctr. (United States)
Thomas S. Pheiffer, Vanderbilt Univ. (United States)
Jared A. Weis, Vanderbilt Univ. (United States)
Thomas E. Yankeelov, Vanderbilt Univ. (United States)
Vanderbilt Univ. Medical Ctr. (United States)
Michael I. Miga, Vanderbilt Univ. (United States)
Vanderbilt Univ. Medical Ctr. (United States)


Published in SPIE Proceedings Vol. 9036:
Medical Imaging 2014: Image-Guided Procedures, Robotic Interventions, and Modeling
Ziv R. Yaniv; David R. Holmes, Editor(s)

© SPIE. Terms of Use
Back to Top