In the paper we present implementation of 3D DIC method for in-situ diagnostic measurements of expansion bellows in heating chambers. The simultaneous measurements of a supply and a return pipeline were carried out in a heating chamber in Warsaw at the peak of the heating season in cooperation with Dalkia Warszawa. Results of the measurements enabled assessment of the risk of failure of expansion bellows. In-situ measurements were preceded by feasibility tests carried out in the Institute of Heat Engineering of Warsaw University of Technology. Potential implementations and a direction of future works are discussed in conclusions.