A numerical method for designing gradient-index fiber probes
Author(s): Chi Wang; Xueqin Xia; Shubo Bi; Xingfei Li; Li Wang; Yingjie Yu
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

A numerical method is investigated to design gradient-index (GRIN) fiber probes. The GRIN fiber probe is composed of a single mode fiber (SMF), a no-core fiber (NCF), and a GRIN fiber lens. The optical software GLAD is adopted to simulate the optical performance of the probe. The simulation results show that, given the length of the GRIN fiber lens 0.1mm and the length of the NCF 0.36mm, the working distance is 0.73mm and the focus spot size 33μm, which are well agreement with the experimental data. As a result, the proposed numerical method is validated to be effective to design such GRIN fiber probes.

Paper Details

Date Published: 22 June 2013
PDF: 6 pages
Proc. SPIE 8769, International Conference on Optics in Precision Engineering and Nanotechnology (icOPEN2013), 87693B (22 June 2013); doi: 10.1117/12.2017818
Show Author Affiliations
Chi Wang, Shanghai Univ. (China)
Xueqin Xia, Shanghai Univ. (China)
Shubo Bi, Shanghai Univ. (China)
Xingfei Li, Tianjin Univ. (China)
Li Wang, Shanghai Institute of Optics and Fine Mechanics (China)
Yingjie Yu, Shanghai Univ. (China)


Published in SPIE Proceedings Vol. 8769:
International Conference on Optics in Precision Engineering and Nanotechnology (icOPEN2013)
Chenggen Quan; Kemao Qian; Anand Asundi, Editor(s)