3D-3D registration of partial capitate bones using spin-images
Author(s): Ryan Breighner; David R. Holmes; Shuai Leng; Kai-Nan An; Cynthia McCollough; Kristin Zhao
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

It is often necessary to register partial objects in medical imaging. Due to limited field of view (FOV), the entirety of an object cannot always be imaged. This study presents a novel application of an existing registration algorithm to this problem. The spin-image algorithm [1] creates pose-invariant representations of global shape with respect to individual mesh vertices. These ‘spin-images,’ are then compared for two different poses of the same object to establish correspondences and subsequently determine relative orientation of the poses. In this study, the spin-image algorithm is applied to 4DCT-derived capitate bone surfaces to assess the relative accuracy of registration with various amounts of geometry excluded.

The limited longitudinal coverage under the 4DCT technique (38.4mm, [2]), results in partial views of the capitate when imaging wrist motions. This study assesses the ability of the spin-image algorithm to register partial bone surfaces by artificially restricting the capitate geometry available for registration. Under IRB approval, standard static CT and 4DCT scans were obtained on a patient. The capitate was segmented from the static CT and one phase of 4DCT in which the whole bone was available. Spin-image registration was performed between the static and 4DCT. Distal portions of the 4DCT capitate (10-70%) were then progressively removed and registration was repeated. Registration accuracy was evaluated by angular errors and the percentage of sub-resolution fitting. It was determined that 60% of the distal capitate could be omitted without appreciable effect on registration accuracy using the spin-image algorithm (angular error < 1.5 degree, sub-resolution fitting < 98.4%).

Paper Details

Date Published: 12 March 2013
PDF: 6 pages
Proc. SPIE 8671, Medical Imaging 2013: Image-Guided Procedures, Robotic Interventions, and Modeling, 867113 (12 March 2013); doi: 10.1117/12.2008685
Show Author Affiliations
Ryan Breighner, Mayo Clinic (United States)
David R. Holmes, Mayo Clinic (United States)
Shuai Leng, Mayo Clinic (United States)
Kai-Nan An, Mayo Clinic (United States)
Cynthia McCollough, Mayo Clinic (United States)
Kristin Zhao, Mayo Clinic (United States)


Published in SPIE Proceedings Vol. 8671:
Medical Imaging 2013: Image-Guided Procedures, Robotic Interventions, and Modeling
David R. Holmes; Ziv R. Yaniv, Editor(s)

© SPIE. Terms of Use
Back to Top