Paper Abstract

Early detection of prostate cancer is critical in maximizing the probability of successful treatment. Current systematic biopsy approach takes 12 or more randomly distributed core tissue samples within the prostate and can have a high potential, especially with early disease, for a false negative diagnosis. The purpose of this study is to determine the accuracy of a 3D ultrasound-guided biopsy system. Testing was conducted on prostate phantoms created from an agar mixture which had embedded markers. The phantoms were scanned and the 3D ultrasound system was used to direct the biopsy. Each phantom was analyzed with a CT scan to obtain needle deflection measurements. The deflection experienced throughout the biopsy process was dependent on the depth of the biopsy target. The results for markers at a depth of less than 20 mm, 20-30 mm, and greater than 30 mm were 3.3 mm, 4.7 mm, and 6.2 mm, respectively. This measurement encapsulates the entire biopsy process, from the scanning of the phantom to the firing of the biopsy needle. Increased depth of the biopsy target caused a greater deflection from the intended path in most cases which was due to an angular incidence of the biopsy needle. Although some deflection was present, this system exhibits a clear advantage in the targeted biopsy of prostate cancer and has the potential to reduce the number of false negative biopsies for large lesions.

Paper Details

Date Published: 14 March 2013
PDF: 8 pages
Proc. SPIE 8671, Medical Imaging 2013: Image-Guided Procedures, Robotic Interventions, and Modeling, 86712H (14 March 2013); doi: 10.1117/12.2007695
Show Author Affiliations
Walter J. Wooten, Emory Univ. (United States)
Jonathan A. Nye, Emory Univ. (United States)
David M. Schuster, Emory Univ. (United States)
Peter T. Nieh, Emory Univ. School of Medicine (United States)
Viraj A. Master, Emory Univ. School of Medicine (United States)
John R. Votaw, Emory Univ. (United States)
Baowei Fei, Emory Univ. (United States)
Georgia Institute of Technology (United States)


Published in SPIE Proceedings Vol. 8671:
Medical Imaging 2013: Image-Guided Procedures, Robotic Interventions, and Modeling
David R. Holmes; Ziv R. Yaniv, Editor(s)

© SPIE. Terms of Use
Back to Top