Share Email Print
cover

Proceedings Paper

Comparative studies of collimator performance in DaTscan (Ioflupane I-123) striatal SPECT
Author(s): Andrzej Krol; Mary A. McGrath; Brian T. Carey; David H. Feiglin
Format Member Price Non-Member Price
PDF $17.00 $21.00

Paper Abstract

Purpose: To determine optimal collimator and gamma camera combination for Ioflupane I-123 (DaTscan) striatal SPECT. Methods: Anthropomorphic basal ganglia phantom was used. The striatal chambers (caudate and putamen chambers) and the large chamber simulating nonspecific background activity in the remainder of the brain were filled with I-123 with the specific activity ratio 7.7. SPECT data were acquired using triple-head gamma camera (THGC) with fan-beam low-energy ultra high-resolution (LEUR) collimators, with dual-head gamma camera (DHGC) with parallel-beam lowenergy high-resolution (LEHR) collimators and medium-energy general-purpose (MEGP) collimators. Data were acquired at 159 keV with a 20% window, with I-123 and Tc-99m flood table for THGC and DHGC, respectively. The images were reconstructed using the OSEM algorithm with resolution modeling and uniform attenuation correction, and Butterworth postfilter, 5th order and 0.64, 0.78 and 1.0 Ny for LEUR, LEHR, and MEGP, respectively. The filter parameters were chosen to optimize the balance between image noise and spatial resolution. Results: The best image quality in terms of spatial resolution and contrast was obtained with fan-beam LEUR/THGC. The MEGP/DHBC produced images with better contrast-to-noise ratio than LEHR/DHGC. The measured ratio of mean activity in striatal chambers to the remainder of the brain was comparable for all three collimator/camera combinations. Conclusions: Based on phantom DaTscan striatal SPECT, the THGC with fan-beam LEUR collimators is preferable. If DHGC is used MEGP collimators provide better image quality, as compared to LEHR. More studies including patient studies are needed to confirm best collimator/camera combination.

Paper Details

Date Published: 29 March 2013
PDF: 5 pages
Proc. SPIE 8672, Medical Imaging 2013: Biomedical Applications in Molecular, Structural, and Functional Imaging, 867204 (29 March 2013); doi: 10.1117/12.2007027
Show Author Affiliations
Andrzej Krol, SUNY Upstate Medical Univ. (United States)
Mary A. McGrath, SUNY Upstate Medical Univ. (United States)
Brian T. Carey, SUNY Upstate Medical Univ. (United States)
David H. Feiglin, SUNY Upstate Medical Univ. (United States)


Published in SPIE Proceedings Vol. 8672:
Medical Imaging 2013: Biomedical Applications in Molecular, Structural, and Functional Imaging
John B. Weaver; Robert C. Molthen, Editor(s)

© SPIE. Terms of Use
Back to Top