Speckle produced by cold cataract
Author(s): Bronislaw Grzegorzewski; Marek Syroczynski; Malgorzata Pyskir
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

The phase separation in eye lens homogenate was investigated. The statistical properties of speckle produced by a thin layer of the homogenate have been experimentally examined. The temperature dependence of the specular component for whole lens and the layer of homogenate was measured. The probability density function of speckle intensity and the average contrast are presented. The statistical parameters of the domains associated with phase separation are estimated.

Paper Details

Date Published: 12 December 1994
PDF: 6 pages
Proc. SPIE 2340, Interferometry '94: New Techniques and Analysis in Optical Measurements, (12 December 1994); doi: 10.1117/12.195952
Show Author Affiliations
Bronislaw Grzegorzewski, Medical Academy of Bydgoszcz and Academy of Technology and Agriculture (Poland)
Marek Syroczynski, Medical Academy of Bydgoszcz (Poland)
Malgorzata Pyskir, Medical Academy of Bydgoszcz (Poland)


Published in SPIE Proceedings Vol. 2340:
Interferometry '94: New Techniques and Analysis in Optical Measurements
Malgorzata Kujawinska; Krzysztof Patorski, Editor(s)

© SPIE. Terms of Use