Study of an on-board data compression system in the imaging spectroscopy
Author(s): Shen-en Qian
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

According to the features of imaging spectrometer a two dimension compression has been converted into a series of one dimension processing. A real-time "two-true-value linear prediction method" which has the ability of on-board compressing the raw data in the spectrum direction has been developed. This method can preserve absorption band information during compression/decompression process. The results show that for most spectra at least 2:1 compression ratio can be obtained under 1% reconstruction accuracy; on an average the raw data rate can be reduced 3-4 times. The arts of coding compressed data, and the reconstruction error have also been described.

Paper Details

Date Published: 1 June 1990
PDF: 12 pages
Proc. SPIE 1244, Image Processing Algorithms and Techniques, (1 June 1990); doi: 10.1117/12.19521
Show Author Affiliations
Shen-en Qian, Changchun Institute of Optics & Fine Mechanics (Canada)

Published in SPIE Proceedings Vol. 1244:
Image Processing Algorithms and Techniques
Robert J. Moorhead; Keith S. Pennington, Editor(s)

© SPIE. Terms of Use