A study was performed to reduce TiW particle contamination in a dc magnetron sputtering system. Significant accomplishments were obtained through simplification of shielding for the process chamber and the use of improved materials of construction. Through the implementation of this enhanced hardware, maintainability benefits were obtained in the areas of shield use (66% reduction), equipment downtime (30% reduction), and maintenance labor (> 3 hours/shield change). In addition to these, overall particle counts were reduced significantly. Lastly, improvements in film uniformity across a wafer were improved by 0.5%, 1 (sigma) , based upon sheet resistivity contour maps.

Paper Details

Date Published: 14 September 1994
PDF: 8 pages
Proc. SPIE 2334, Microelectronics Manufacturability, Yield, and Reliability, (14 September 1994); doi: 10.1117/12.186769