In a reinforced concrete wall the deformation during concrete hardening was measured by means of embedded extrinsic fibre-Fabry-Perot-interferometers. The sensors were specifically modified in order to provide a self-calibration cycle and to ensure the functional efficiency under adverse conditions at the building site. The installation was done in the wall's cage of reinforcement before its concreting. The measurement was carried out automatically over a period of 35 days. The measuring results are very satisfactory and give a resolution of 0.1 micrometers /m.

Paper Details

Date Published: 13 September 1994
PDF: 4 pages
Proc. SPIE 2361, Second European Conference on Smart Structures and Materials, (13 September 1994); doi: 10.1117/12.184820
Show Author Affiliations
Wolfgang R. Habel, Institute for Maintenance and Modernization of Structures (Germany)
Detlef Hofmann, Institute for Maintenance and Modernization of Structures (Germany)