Temporal behavior of electric field at triple junction and its relation to flashover of bridged vacuum gaps
Author(s): O. Yamamoto; T. Hara; H. Matsuura; Masayasu Hayashi; K. Yukimura
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Temporal change in electric field strength at the insulator-cathode-vacuum interface accompanied by charging of the insulator have been studied by using a 2D Monte Carlo simulation. The study employed cylindrical insulators and conical insulators. Each of the insulators was made of PMMA, polyimide or Al2O3. The field strength with cylindrical insulators show an abrupt increase, and with conical insulators considerable rapid reduction. Dependencies of the field change on the applied voltage height and material are well demonstrated. Flashovers occur after the simulated field change.

Paper Details

Date Published: 1 May 1994
PDF: 4 pages
Proc. SPIE 2259, XVI International Symposium on Discharges and Electrical Insulation in Vacuum, (1 May 1994); doi: 10.1117/12.174676
Show Author Affiliations
O. Yamamoto, Kyoto Univ. (Japan)
T. Hara, Kyoto Univ. (Japan)
H. Matsuura, Kyoto Univ. (Japan)
Masayasu Hayashi, Kyoto Univ. (Japan)
K. Yukimura, Doshisha Univ. (Japan)


Published in SPIE Proceedings Vol. 2259:
XVI International Symposium on Discharges and Electrical Insulation in Vacuum
Gennady A. Mesyats, Editor(s)