Nontomographical volume reconstruction and density bounding from images generated by a conical fan beam of resonantly absorbed radiation
Author(s): Yair Shimoni; Asher Saya; Yair Shamai; Doron Bar; Rami Perel; Ronald A. Krauss
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

We describe a method of reconstructing the volume, and of estimating the lower bound of the density, of objects absorbing radiation by resonant (gamma-proton) reactions. The method is easily adapted to conical beams. The advantages of the imaging method to the detection of explosives in laboratory system based on nuclear resonance absorption are examined. The results of applying the method to the inspection of nitrogenous objects are presented, including the usefulness of oversampling and the relative success of differentiating explosives from innocuous materials based on nitrogen densities.

Paper Details

Date Published: 28 March 1994
PDF: 10 pages
Proc. SPIE 2092, Substance Detection Systems, (28 March 1994); doi: 10.1117/12.171277
Show Author Affiliations
Yair Shimoni, IAI/MBT Systems (Israel)
Asher Saya, Soreq Nuclear Research Ctr. (Israel)
Yair Shamai, Soreq Nuclear Research Ctr. (Israel)
Doron Bar, Soreq Nuclear Research Ctr. (Israel)
Rami Perel, Soreq Nuclear Research Ctr. (Israel)
Ronald A. Krauss, FAA Technical Ctr. (United States)