New results for prediction of cutting tools wearing resistance using one- and two-side transient thermal NDT method
Author(s): Vladimir P. Vavilov; V. A. Pushnykh; V. Tsipilev; A. V. Shipulin; Ermanno G. Grinzato
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

This paper contains experimental results obtained by applying both one-side and two-side diffusivity measurement procedure for Russian-made cutting tools. Experimental set included CO2 laser with energy up to 12 J in 4 ms pulse and diffusivity measurement device TAU- 1. In two-side test the correlation coefficient between wear resistance and obtained value of diffusivity was estimated to be K equals -0.61. In one-side test the ratio of signals at 6 and 9 ms after flash was accepted as wear resistance criterion. The corresponding correlation coefficient was K equals 0.59. Some results obtained with Swedish-made tools of unknown composition are also discussed.

Paper Details

Date Published: 21 March 1994
PDF: 6 pages
Proc. SPIE 2245, Thermosense XVI: An International Conference on Thermal Sensing and Imaging Diagnostic Applications, (21 March 1994); doi: 10.1117/12.171166
Show Author Affiliations
Vladimir P. Vavilov, ITEF-CNR (Italy)
V. A. Pushnykh, Tomsk Polytechnic Univ. (Russia)
V. Tsipilev, Tomsk Polytechnic Univ. (Russia)
A. V. Shipulin, Tomsk Polytechnic Univ. (Russia)
Ermanno G. Grinzato, ITEF-CNR (Italy)