Optimization and comparison of multipole wiggler and bending magnet sources of synchrotron radiation for x-ray experiments
Author(s): Gert E. van Dorssen; Howard A. Padmore; W. Joho
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

The useful flux received in an experiment will depend both on the characteristics of the source and on the characteristics of the experiment. It is therefore necessary when optimizing the design of a synchrotron radiation source to take full account of the experimental requirements and not simply to optimize the integrated flux or brilliance. A method of optimization used for multipole wigglers and bending magnets is described, and applied to a proposed 3 GeV source at Daresbury, DIAMOND, and the proposed 2.1 GeV Swiss Light Source, SLS.

Paper Details

Date Published: 29 November 1993
PDF: 11 pages
Proc. SPIE 2013, Electron-Beam Sources of High-Brightness Radiation, (29 November 1993); doi: 10.1117/12.164791
Show Author Affiliations
Gert E. van Dorssen, SERC Daresbury Lab. (United Kingdom)
Howard A. Padmore, SERC Daresbury Lab. (United Kingdom)
W. Joho, Paul Scherer Institut (Switzerland)


Published in SPIE Proceedings Vol. 2013:
Electron-Beam Sources of High-Brightness Radiation
Henry P. Freund, Editor(s)