Share Email Print
cover

Proceedings Paper

Test results from a pumped single-phase porous metal heat exchanger
Author(s): John H. Rosenfeld; Richard Schumacher; Robert D. Watson; Jimmie M. McDonald
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

A pumped single-phase porous metal cooled microwave cavity design is being evaluated for use in a high-power gyrotron. A small-scale porous metal cooled test article was designed, built, and tested on a Phase I SBIR program. The program was funded by the United States Department of Energy. A copper/water porous metal heat exchanger test article was fabricated and was subsequently tested at absorbed heat fluxes up to 7.4 +/- 0.3 kW/cm2 before failure occurred. Multiple tests were successfully completed at heat fluxes of 4.0 to over 6.0 W/cm2 with no signs of failure. The test article design, coolant parameters, test methodology, and test results are presented. The results of this work show the potential of porous metal cooling to solve a number of high heat flux cooling problems; several such applications are described.

Paper Details

Date Published: 12 November 1993
PDF: 12 pages
Proc. SPIE 1997, High Heat Flux Engineering II, (12 November 1993); doi: 10.1117/12.163828
Show Author Affiliations
John H. Rosenfeld, Thermacore, Inc. (United States)
Richard Schumacher, Varian Associates, Inc. (United States)
Robert D. Watson, Sandia National Labs. (United States)
Jimmie M. McDonald, Sandia National Labs. (United States)


Published in SPIE Proceedings Vol. 1997:
High Heat Flux Engineering II
Ali M. Khounsary, Editor(s)

© SPIE. Terms of Use