An infrared laser Stark spectrometer has been developed to measured NH3 concentrations in hot flue gas. The main application is the determination of ammonia slip after NOx- reduction with NH3 in power stations and chemical plants. Physical parameters that influence the results of measurements are tracked and their behavior is explained in terms of line shapes. A description of the instrument is given and results of NH3 measurements in flue gas are presented.