Share Email Print
cover

Optical Engineering

U.S. Air Force Aerial Camera Resolution Tester
Author(s): C. C. Wheeler
Format Member Price Non-Member Price
PDF $20.00 $25.00

Paper Abstract

An assembly of 14 diffraction limited collimators project beams, up to 12 in. (30.5 cm) in diameter, into the aperture of an aerial camera under test. USAG 1951 targets, both standard and Cos/Cos2 corrected, are provided for off-axis angles of 0° to 60°. The collimators, targets, and camera are mounted on a rigid, isolated, vertical frame, 29 ft. (880 cm) high and 28 ft. (850 cm) wide. The building and air-conditioning requirements are also discussed.

Paper Details

Date Published: 1 April 1975
PDF: 4 pages
Opt. Eng. 14(2) 142120 doi: 10.1117/12.7978740
Published in: Optical Engineering Volume 14, Issue 2
Show Author Affiliations
C. C. Wheeler, The Perkin-Elmer Corporation (United States)