Share Email Print
cover

Optical Engineering

Study On Infrared Gas-Filter Correlation Spectrometer For Measuring Low-Concentration Methanol Gases
Author(s): Soyoung Cha; Peter A. Gabele
Format Member Price Non-Member Price
PDF $20.00 $25.00

Paper Abstract

A gas-filter correlation spectrometer that employed a wide spectral band of infrared radiation and gas-filter cell has been built and successfully tested to measure methanol concentrations up to 113 ppm. The instrument demonstrates a detection limit of approximately 1.0 um. The interference of nonmethanol gases is negligible when automobile exhausts are used for the test. The most prominent, though not serious, problem appears to be the signal drift, which is believed to be improved by thermally insulating the instrument. The analyzer demonstrated its capability for real-time analysis of emissions from methanol-fueled vehicles due to its simplicity and fast response as compared with wet chemical methods.

Paper Details

Date Published: 1 December 1986
PDF: 5 pages
Opt. Eng. 25(12) doi: 10.1117/12.7974002
Published in: Optical Engineering Volume 25, Issue 12
Show Author Affiliations
Soyoung Cha, University of Illinois at Chicago (United States)
Peter A. Gabele, U. S. Environmental Protection Agency (United States)


© SPIE. Terms of Use