Uniform frontal illumination of planar surfaces: where to place the lamps
Author(s): Michael A. Gennert; Norman Wittels; Gary L. Leatherman
Format Member Price Non-Member Price
PDF $20.00 $25.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

A method is presented for placing line, point, and ring light sources to produce uniform illumination of planar surfaces. Optimization consists in setting to zero as many terms as possible in a two-dimensional Taylor series expansion of the surface illumination. We analyze several practical lighting arrangements and discuss the significance of symmetry in lighting design. Four conditions are sufficient to produce optimal illumination: (1) place all lamps in a single plane parallel to the illuminated surface; (2) arrange linear sources in parallel pairs; (3) arrange point-source lamps to achieve fourfold symmetry with respect to any two orthogonal axes lying in the surface, this requires a minimum of four lamps; and (4) select lamp heights so that a line connecting each lamp to the center of the illuminated surface forms specific angles with the surface normal: 30 deg for line sources and approximately 39 deg for point and ring sources. Any lamp arrangement meeting these conditions produces an illumination function in which at least three orders of terms of the Taylor series expansion are zero. We also discuss circumstances under which some of these conditions can be relaxed.

Paper Details

Date Published: 1 June 1993
PDF: 11 pages
Opt. Eng. 32(6) doi: 10.1117/12.135853
Published in: Optical Engineering Volume 32, Issue 6
Show Author Affiliations
Michael A. Gennert, Worcester Polytechnic Institute (United States)
Norman Wittels, Worcester Polytechnic Institute (United States)
Gary L. Leatherman, Science Applications International Corp. (United States)