Share Email Print
cover

Optical Engineering

Location optimization of remote gain unit in ultralong span repeaterless optical transmission system
Author(s): Huang Xiong; Yuanyuan Shan; Junqiang Sun
Format Member Price Non-Member Price
PDF $20.00 $25.00

Paper Abstract

The influences of the remote gain unit (RGU) location on ultralong span repeaterless optical transmission system with different bit rates and the number of the signal channels is discussed in this paper. The experimental results show that the optimal location of the RGU can always exist for obtaining the minimum signal bit error rate at receiver with a fixed transmission distance. The optimization location of the RGU is entirely dependent on the total transmission length and the number of channel in the wavelength division multiplexing (WDM) system. When the 1480-nm pump power is set about 1 W, the span of the repeaterless WDM transmission system can be extended to 402 km through optimizing the location of the RGU. The optimal configuration scheme of the RGU can provide a potential application to increase the transmission spans for undersea transmission systems, electric power transmission systems, and the other special trades.

Paper Details

Date Published: 9 March 2017
PDF: 4 pages
Opt. Eng. 56(3) 036106 doi: 10.1117/1.OE.56.3.036106
Published in: Optical Engineering Volume 56, Issue 3
Show Author Affiliations
Huang Xiong, Huazhong Univ. of Science and Technology (China)
Yuanyuan Shan, Huazhong Univ. of Science and Technology (China)
Junqiang Sun, Huazhong Univ. of Science and Technology (China)


© SPIE. Terms of Use