Share Email Print
cover

Journal of Applied Remote Sensing

Absolute radiometric calibration of the KOMPSAT-2 multispectral camera using a reflectance-based method and empirical comparison with IKONOS and QuickBird images
Author(s): Sun Gu Lee; Cheong-Gil Jin; Chul Uong Choi; Hyo-Suk Lim; Yongseung Kim; Jinsoo Kim
Format Member Price Non-Member Price
PDF $20.00 $25.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

This paper presents absolute radiometric calibration coefficients (gains) that explain the relationship between the digital number (DN) and at-sensor radiance for the multispectral camera (MSC) on Korea's first high-resolution satellite (KOMPSAT-2). Absolute radiometric calibration was performed using a reflectance-based method. In addition, the suitability of vicarious results from radiance- and reflectance-based validations was analyzed with reference to IKONOS and QuickBird images. The latter are spectrally similar to KOMPSAT-2 images and have been validated in a large number of studies. For all bands, the R2 values of fitted lines for the gain ranged from 0.82 to 0.94, representing an improvement compared to previous findings for the KOMPSAT-2 MSC. To analyze the suitability of the vicarious results, same-pixel at-sensor radiances across different spectral bands were compared. In all bands, except the red band of QuickBird, the at-sensor radiances of KOMPSAT-2 MSC were highly correlated with those of IKONOS and QuickBird. In addition, same-pixel comparisons of reflectance across different spectral bands showed that the slopes of the least-squares lines for each band were similar to the results of the radiance comparison. The standard deviation among top of atmosphere (TOA) reflectances was within 0.019 for all bands. To calculate the tasseled cap transformation (TCT) coefficients for the KOMPSAT-2 MSC, an empirical method was applied using radiometric normalization. The results were similar to those obtained using the TCT coefficients for IKONOS and QuickBird in the brightness, greenness, and wetness components. The TCT images showed similar patterns. The absolute radiometric calibration coefficients presented here appear to be a good standard for maintaining the optical quality of the KOMPSAT-2 MSC, for which prelaunch, on-board, and vicarious calibration data are lacking.

Paper Details

Date Published: 30 October 2012
PDF: 26 pages
J. Appl. Remote Sens. 6(1) 063594 doi: 10.1117/1.JRS.6.063594
Published in: Journal of Applied Remote Sensing Volume 6, Issue 1
Show Author Affiliations
Sun Gu Lee, Korea Aerospace Research Institute (Korea, Republic of)
Cheong-Gil Jin, Korea Aerospace Research Institute (Korea, Republic of)
Chul Uong Choi, Pukyong National Univ. (Korea, Republic of)
Hyo-Suk Lim, Korea Aerospace Research Institute (Korea, Republic of)
Yongseung Kim, Korea Aerospace Research Institute (Korea, Republic of)
Jinsoo Kim, ZEN21 (Korea, Republic of)


© SPIE. Terms of Use
Back to Top